Discount Lock & Safe
install Rosslare Security Products.
Access control is a system which enables an authority to control access to areas and resources in a given physical facility or computer-based information system. An access control system, within the field of physical security, is generally seen as the second layer in the security of a physical structure.

Access control is, in reality, an everyday phenomenon. A lock on a car door is essentially a form of access control. A PIN on an ATM system at a bank is another means of access control. Bouncers standing in front of a night club is perhaps a more primitive mode of access control (given the evident lack of information technology involved). The possession of access control is of prime importance when persons seek to secure important, confidential, or sensitive information and equipment.

Item control or electronic key management is an area within (and possibly integrated with) an access control system which concerns the managing of possession and location of small assets or physical (mechanical) keys.

Physical access by a person may be allowed depending on payment, authorization, etc. Also there may be one-way traffic of people. These can be enforced by personnel such as a border guard, a doorman, a ticket checker, etc., or with a device such as a turnstile. There may be fences to avoid circumventing this access control. An alternative of access control in the strict sense (physically controlling access itself) is a system of checking authorized presence, see e.g. Ticket controller (transportation). A variant is exit control, e.g. of a shop (checkout) or a country.

In physical security, the term access control refers to the practice of restricting entrance to a property, a building, or a room to authorized persons. Physical access control can be achieved by a human (a guard, bouncer, or receptionist), through mechanical means such as locks and keys, or through technological means such as access control systems like the Access control vestibule. Within these environments, physical key management may also be employed as a means of further managing and monitoring access to mechanically keyed areas or access to certain small assets.

Physical access control is a matter of who, where, and when. An access control system determines who is allowed to enter or exit, where they are allowed to exit or enter, and when they are allowed to enter or exit. Historically this was partially accomplished through keys and locks. When a door is locked only someone with a key can enter through the door depending on how the lock is configured. Mechanical locks and keys do not allow restriction of the key holder to specific times or dates. Mechanical locks and keys do not provide records of the key used on any specific door and the keys can be easily copied or transferred to an unauthorized person. When a mechanical key is lost or the key holder is no longer authorized to use the protected area, the locks must be re-keyed.

Electronic access control uses computers to solve the limitations of mechanical locks and keys. A wide range of credentials can be used to replace mechanical keys. The electronic access control system grants access based on the credential presented. When access is granted, the door is unlocked for a predetermined time and the transaction is recorded. When access is refused, the door remains locked and the attempted access is recorded. The system will also monitor the door and alarm if the door is forced open or held open too long after being unlocked.

Access control system operation
When a credential is presented to a reader, the reader sends the credential’s information, usually a number, to a control panel, a highly reliable processor. The control panel compares the credential's number to an access control list, grants or denies the presented request, and sends a transaction log to a database. When access is denied based on the access control list, the door remains locked. If there is a match between the credential and the access control list, the control panel operates a relay that in turn unlocks the door. The control panel also ignores a door open signal to prevent an alarm. Often the reader provides feedback, such as a flashing red LED for an access denied and a flashing green LED for an access granted.

The above description illustrates a single factor transaction. Credentials can be passed around, thus subverting the access control list. For example, Alice has access rights to the server room but Bob does not. Alice either gives Bob her credential or Bob takes it; he now has access to the server room. To prevent this, two-factor authentication can be used. In a two factor transaction, the presented credential and a second factor are needed for access to be granted; another factor can be a PIN, a second credential, operator intervention, or a biometric input.

There are three types (factors) of authenticating information:

something the user knows, eg a password, pass-phrase or PIN
something the user has, such as smart card
something the user is, such as fingerprint, verified by biometric measurement
Passwords are a common means of verifying a user's identity before access is given to information systems. In addition, a fourth factor of authentication is now recognized: someone you know, where another person who knows you can provide a human element of authentication in situations where systems have been set up to allow for such scenarios. For example, a user may have their password, but have forgotten their smart card. In such a scenario, if the user is known to designated cohorts, the cohorts may provide their smart card and password in combination with the extant factor of the user in question and thus provide two factors for the user with missing credential, and three factors overall to allow access.

Credential
A credential is a physical/tangible object, a piece of knowledge, or a facet of a person's physical being, that enables an individual access to a given physical facility or computer-based information system. Typically, credentials can be something you know (such as number or PIN), something you have (such as an access badge), something you are (such as a biometric feature) or some combination of these items. The typical credential is an access card, key fob, or other key. There are many card technologies including magnetic stripe, bar code, Wiegand, 125 kHz proximity, 26 bit card-swipe, contact smart cards, and contactless smart cards. Also available are key-fobs which are more compact than ID cards and attach to a key ring. Typical biometric technologies include fingerprint, facial recognition, iris recognition, retinal scan, voice, and hand geometry.

Access control system components
An access control point, which can be a door, turnstile, parking gate, elevator, or other physical barrier where granting access can be electronically controlled. Typically the access point is a door. An electronic access control door can contain several elements. At its most basic there is a stand-alone electric lock. The lock is unlocked by an operator with a switch. To automate this, operator intervention is replaced by a reader. The reader could be a keypad where a code is entered, it could be a card reader, or it could be a biometric reader. Readers do not usually make an access decision but send a card number to an access control panel that verifies the number against an access list. To monitor the door position a magnetic door switch is used. In concept the door switch is not unlike those on refrigerators or car doors. Generally only entry is controlled and exit is uncontrolled. In cases where exit is also controlled a second reader is used on the opposite side of the door. In cases where exit is not controlled, free exit, a device called a request-to-exit (RTE) is used. Request-to-exit devices can be a pushbutton or a motion detector. When the button is pushed or the motion detector detects motion at the door, the door alarm is temporarily ignored while the door is opened. Exiting a door without having to electrically unlock the door is called mechanical free egress. This is an important safety feature. In cases where the lock must be electrically unlocked on exit, the request-to-exit device also unlocks the door.

Access control topology

Typical access control door wiring
Access control door wiring when using intelligent readersAccess control decisions are made by comparing the credential to an access control list. This lookup can be done by a host or server, by an access control panel, or by a reader. The development of access control systems has seen a steady push of the lookup out from a central host to the edge of the system, or the reader. The predominate topology circa 2009 is hub and spoke with a control panel as the hub and the readers as the spokes. The lookup and control functions are by the control panel. The spokes communicate through a serial connection; usually RS485. Some manufactures are pushing the decision making to the edge by placing a controller at the door. The controllers are IP enabled and connect to a host and database using standard networks.

Types of readers
Access control readers may be classified by functions they are able to perform:

Basic (non-intelligent) readers: simply read card number or PIN and forward it to a control panel. In case of biometric identification, such readers output ID number of a user. Typically Wiegand protocol is used for transmitting data to the control panel, but other options such as RS-232, RS-485 and Clock/Data are not uncommon. This is the most popular type of access control readers.

Semi-intelligent readers: have all inputs and outputs necessary to control door hardware (lock, door contact, exit button), but do not make any access decisions. When a user presents a card or enters PIN, the reader sends information to the main controller and waits for its response. If the connection to the main controller is interrupted, such readers stop working or function in a degraded mode. Usually semi-intelligent readers are connected to a control panel via an RS-485 bus.
Intelligent readers: have all inputs and outputs necessary to control door hardware, they also have memory and processing power necessary to make access decisions independently. Same as semi-intelligent readers they are connected to a control panel via an RS-485 bus. The control panel sends configuration updates and retrieves events from the readers.  There is also a new generation of intelligent readers referred to as "IP readers". Systems with IP readers usually do not have traditional control panels and readers communicate directly to PC that acts as a host.  Some readers may have additional features such as LCD and function buttons for data collection purposes (i.e. clock-in/clock-out events for attendance reports), camera/speaker/microphone for intercom, and smart card read/write support.

Access control readers may also be classified by the type of identification technology.

Access Control, Greenville SC, Audit Trail Easley, Piedmont and Simpsonville, SC